BXWCN - JAN6303 ELECTRON TUBE

Product Identification

Product ID:JAN6303 ELECTRON TUBE
MSDS Date:06/05/1996
FSC:5960
NIIN:00-804-0954
MSDS Number: BXWCN

Responsible Party
TRITON SVCS (ELECTRON TECHNOLOGY DIV)
3100 CHARLOTTE AVE
EASTON, PA 18042
US

Emergency Phone: 215-252-7331

Info Phone: 215-252-7331

Cage: MO002

Contractor
TRITON SVCS (ELECTRON TECHNOLOGY DIV)
100 EASTON, PA 18042 US

Telephone: 215-252-7331

Cage: MO002

Ingredients

THORIUM-232 = 85 MILLIGRAMS = 0.0218 MICROCURIES

CAS: 7440-29-1

RTECS: XO6400000

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ELECTRON TUBES HAVE THE FOLLOWING
HAZARDS ASSOCIATED WITH THEM: HIGH VOLTAGE, RF RADIATION, X-RAY
RADIATION, POSSIBLE BEYLLIUM OXIDE POISONONG, CORROSIVE & POISONOUS
COMPOUNDS, IMPLOSION HAZARDS, HOT COOLANT AND/OR STEAM, HOT
SURFACES. ONEOR MORE MAY PRESENT IN THIS TUBE.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GRATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:PERSONS WITH PACEMAKERS SHOULD NOT
WORK AROUND EXPOSED ELECTRON TUBES; RF RADIATION MAY AFFECT
OPERATION OF THE PACEMAKER.

First Aid

First Aid:DLA-HMIS:IF EXPOSED TO BROKEN TUBE: INHALED-MOVE TO FRESH
AIR. GIVE RESPIRATORY SUPPORT AS NEEDED. IF SYMPTOMS DEVELOP, SEE
DOCTOR. SKIN- IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.
EYES-IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES. REMOVEPERSON TO
FRESH AIR. INGESTION-GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:WEAR PROTECTIVE EQUIPMNET. SWEEP UP AND PLACE
IN CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:ALWAYS HANDLE WITH CARE AVOIDING
EXCESSIVE SHOCK OR VIBRRATION. STORE IN A PROTECTED AREA IN
ORIGINAL CONTAINERS.
Other Precautions:OBSERVE "THIS SIDE UP" INSTRUCTIONS IF PROVIDED ON
SIDE OF CONTAINER.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED. WEAR DUST MASK WHEN
CLEANING OR REMOVING BROKEN TUBES
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:NONE NORMALLY, VINYL FOR BROKNE TUBES.
Eye Protection:NONE SPECIFIED BY MANUFACTURER.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
TRITON SENT A LETTER DATED 05 JUN96 ABOUT THIS PART THAT THIS TUBE
CONTAINS 0.085 GRAMS OF THORIUM AND .0218 MICROCURIES OF
RADIOACTIVITY.

Chemical Properties

HCC:A2
Appearance and Odor:SEALED GLASS TUBE
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:NO
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:BROKEN DEVICE OR FIRE.
Hazardous Decomposition Products:VARIOUS TOXIC FUMES, DEPENDING ON
MAKE-UP OF TUBE.

Disposal

Waste Disposal Methods:MANUFACTURER WILL DISPOSE OF TUBES AT NO CHARGE
PROVIDED THEY ARE RETURNED FREIGHT PREPAID WITH A WRITTEN REQUEST
FOR DISPOSAL. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REG ULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.